Rotary gas meter rvg g100. Rotary gas meters RVG. Rotary gas meter RVG is reliable, accurate and affordable

6. Automation and secondary devices 7. Analytics

Teplopribor Group of Companies (GC) (Teplopribor, Prompribor, Teplokontrol, etc.)- these are devices and automation for measuring, monitoring and regulating the parameters of technological processes (flow metering, heat control, heat metering, control of pressure, level, properties and concentration, etc.).

At the manufacturer's price, products are shipped from both our own production and our partners - leading factories - manufacturers of instrumentation, control equipment, control systems and equipment technological processes- APCS (much is available in the warehouse or can be manufactured and shipped as soon as possible).

RVG meters rotary gas

RVGrotary gas meters(G16; G25; G40; G65; G100; G160; G250; G400) are used for technological and commercial accounting of the volume of non-aggressive, dried and purified gases: natural and city gases, propane, air, nitrogen, inert gases, etc. in heat and power plants industrial, municipal and other enterprises.

Rotary gas meter RVG works on the principle of displacement of a strictly defined volume of gas by rotating rotors. The volume of the displaced gas is determined by the volume of the meter measuring chamber formed by inner surface body and surfaces of two rotors synchronously rotating in opposite directions. The rotary motion of the rotors is transmitted through the gearbox and the magnetic coupling to an 8-bit counting mechanism, which registers the number of rotors' revolutions, and, consequently, the volume of gas that has passed through the meter.

Gas meter RVG records the volume of gas under operating conditions. To bring the measured gas volume to the volume at standard conditions counter RVG can be equipped with electronic correctors EK270, EK260 or TC220, TC215, TC210.

Distinctive features of the gas meterRVG

- Range of measured flow rates from 0.6 m³ / h to 650 m³ / h;

- Working gas pressure no more than 1.6 MPa;

- Flow rate measurement range Q min / Q max: up to 1: 160

- Temperature ranges:

environment from -40 to + 70 ° С;

measured medium from -30 to + 70 ° С;

- Limits of permissible relative error of the basic version:

no more than ± 1% in the flow rate range from 0.1Q max to Q max;

no more than ± 2% in the flow rate range from Q min to 0.1Q max;

- The limits of the permissible relative error of the additional version, which has the letter "U" in the designation:

no more than ± 1% in the flow rate range from 0.05Q max to Q max;

no more than ± 2% in the flow rate range from Q min to 0.05Q max;

- Calibration interval 5 years.

The main characteristics of the gas meterRVG

- high metrological characteristics;

wide range measurable costs;

- low pressure loss across the meter;

- high-speed performance and high accuracy in the pulsed mode of operation;

- no requirements for the length of straight sections, misalignment of the meter and the pipeline and the degree of non-circularity of the pipeline;

- installation in horizontal and vertical sections of the pipeline;

- independence of the measurement accuracy from the pressure and the nature of the gas flow in the network;

- the ability to work with electronic correctors EK270, EK260 *, EK-88 *, TS220, TS215 *, TS210 *, TS-90 *;

- possibility of using high-frequency A1K and medium-frequency R300 sensor in SG-EK complexes with EK270 corrector to control gas flow;

- non-volatility.

* - electronic proofreaders are out of production

Counter type Sensitivity threshold, m3 / h Flow rate range, Qmax / Qmin Qmax, m3 / h 2 * LF (E1), imp / m3 (standard) HF (A1K), imp / m3 (optional) Differential P at Qmax, Pa
G16 0,1 1:30 25 10 14025 45
G25 0,1 1:30; 1:50; 1:65 40 10 14025 75
G40 0,1 1:30; 1:50; 1:65; 1:80 65 10 14025 180
G65 0,1 100 10 14025 390
G100 0,16 1:30; 1:50; 1:65; 1:80; 1:100; 1:160 160 1 7528 390
G160 0,25 1:30; 1:50; 1:65; 1:80; 1:100; 1:160 250 1 3882 525
G250 0,40 1:30; 1:50; 1:65; 1:80; 1:100; 1:160 400 1 3187 975
G400 (Dy100) 0,65 1:30; 1:50; 1:65; 1:80; 1:100; 1:160 650 1 2191 1100
G400 (Dy150) 0,65 1:30; 1:50; 1:65; 1:80; 1:100; 1:160 650 1 2191 1100

Two low-frequency E1 impulse transducers (reed contact), one of which, when working with an electronic corrector, is used to count impulses, the other to ensure the possibility of monitoring unauthorized interference. By special order RVG gas meters are equipped with an E300 medium-frequency sensor and an A1K high-frequency sensor. Combination different types pulse sensors allows you to use gas meter RVG in systems of automatic regulation and control.

Documentation Prices Consultation and order

Teplocom-Service Moscow is ready to accept your application for a gas meter rotary RVG... This model is available to you for ordering and can be promptly delivered to your address. The specialization of our company is gas equipment, therefore, the offer includes a full range of services for the client:

  • sale of meters;
  • warranty obligations;
  • after-sales service of the purchased equipment;
  • installation and customization services;
  • verification services;
  • repair services.
The specialists of the company have solid qualifications and have dealt with both sales and operation of this model. You can trust us and it is profitable to buy a rotary gas meter RVG - the price from the manufacturer is a good incentive for cooperation. In addition to ordering equipment, it is possible to order meter installation and maintenance. You will be provided with a professional service with the ability to get any advice on the model you are interested in.

All standard sizes are available, including:

  • G-100
  • G-160
  • G-250
  • G-400
  • G-400.
The selection of equipment can be performed by our employee based on your application. We hope you are taking advantage of this opportunity. Popular models is a rotary gas meter G16, G40, G65, etc. Our warehouse has a sufficient stock of products to choose from for your parameters. You can start ordering now.

Rotary gas meter RVG is reliable, accurate and affordable

The scope of this model is quite extensive. The product can be used to measure the consumption of gases that belong to the non-aggressive group, taking into account the performed drying and cleaning of the gas. These are the groups of gases: Rotary gas meter RVG G16, G40, G65 and its other standard sizes are used for technological or commercial metering. It is most often used in enterprises, for example, in industrial heat and power plants, in utilities, etc.

The principle of operation of this model is based on the technology of displacement of a strictly defined volume of gas by rotors that rotate. The movement of the rotors is transmitted to a counting mechanism, which records the number of revolutions of the rotors. Thus, the gas volume is calculated.

It is important to emphasize that the rotary gas meter G40, G16 - up to the standard size G400, keeps track of the gas consumption under operating conditions. To bring the volume to standard conditions, this model is equipped with electronic correctors of the following types:

  • EK270;
  • EK260;
  • TC220;
  • TC215;
  • TC210.
You can order any optional equipment to this model. There is a possibility of completing it with the above-mentioned electronic correctors or high-frequency and mid-frequency sensors: A1K, R300.

Benefits and distinctive features:

  • high metrological characteristics;
  • a wide range of measured costs;
  • low pressure loss across the meter;
  • high-speed performance and high accuracy in the pulsed mode of operation;
  • no requirements for the length of straight sections, misalignment of the meter and the pipeline, the degree of non-circularity of the pipeline;
  • installation in horizontal and vertical sections of the pipeline;
  • independence of measurement accuracy from pressure and nature of gas flow in the network;
  • the ability to work with electronic correctors EK270, TS220, Corus, SPG742
  • possibility of using high-frequency A1K and medium-frequency R300 sensor in SG-EK complexes with EK270 corrector to control gas flow;
  • energy independence.
  • The range of measured flow rates is from 0.6 m³ / h to 650 m³ / h;
  • Working gas pressure no more than 1.6 MPa;
  • Flow rate measurement range Qmin / Qmax: up to 1: 160
  • Temperature ranges:
  • environment from -40 to + 70 ° С;
  • measured medium from -30 to + 70 ° С;

Limits of permissible relative error of the basic version:

  • no more than ± 1% in the flow rate range from 0.1Qmax to Qmax;
  • no more than ± 2% in the flow rate range from Qmin to 0.1Qmax;

The limits of the permissible relative error of the additional version, which has the letter "U" in the designation:

  • no more than ± 1% in the flow rate range from 0.05Qmax to Qmax;
  • no more than ± 2% in the flow rate range from Qmin to 0.05Qmax;
  • Calibration interval 5 years.

Measuring ranges of the rotary gas meter RVG:

Standard size

Conditional

passage

Du, mm

m 3 / h

Range of operating flow rates Q min / Q max

Pressure drop, Pa

Qmin, m 3 / h

Rotary gas meters RVG type are designed to measure the volume of gas (cleaned and dried: natural and city gas, propane, nitrogen, compressed air and inert gases) in thermal power plants of industrial, municipal and other enterprises, for commercial metering of consumed gas. For the record OXYGEN using the counter forbidden!

A filter must be installed in front of the meter to clean the gas from mechanical impurities (the size of solid particles in the measured gas, according to the largest measured value, should not exceed 0.08 mm).

The RVG gas meter registers the gas volume under operating conditions. To bring the measured gas volume to the volume under standard conditions, the RVG meter can be equipped with electronic correctors EK270 or TC220.

Distinctive features of RVG gas meters:

  • high reliability and accuracy of measurement with pulsating and intermittent gas flow rates
  • low inertia of the mechanical system
  • wide measuring range
  • low pressure loss across the meter
  • no requirements for the length of straight sections, meter misalignment and the degree of out-of-roundness of the pipeline
  • the ability to work with electronic proofreaders EK-270, TS-220
  • work on horizontal and vertical sections of the gas pipeline
  • independence of measuring accuracy from gas pressure in the network
For remote transmission of information, incl. to an electronic corrector of the EK type (for temperature and pressure) or TC (for temperature), a low-frequency impulse sensor (reed switch) of the IN-S10 type can be connected to the meter, which is triggered by a magnetic insert built into the least significant bit of the counting mechanism.

Main technical characteristics

Product parameters RVG G16 RVG G25 RVG G40 RVG G65 RVG G100 RVG G160 RVG G250 RVG G400
Ambient temperature range, ° С from -40 to +70
Measured medium temperature range, ° С from -30 to +70
Maximum operating pressure, MPa (kgf / cm²) 1,6 (16)
Nominal diameter, mm 50 80 100 100 / 150
Maximum throughput at a pressure close to atmospheric, m³ / hour 25 40 65 100 160 250 400 650
Gas volume measurement range, Q min / Q max 1:30 1:30, 1:50, 1:65 1:30, 1:50, 1:65, 1:80 1:30, 1:50, 1:65, 1:80, 1:100, 1:160
Measurement error of RVG gas meters no more than ± 1% in the flow rate range from 0.1Q max to Q max
no more than ± 2% in the flow rate range from Q min to 0.1Q max
Overall dimensions, mm - length L 171 241 260
- width B 335 435 469 529 660
- height H 222 278 308
Weight, kg, no more 12 16 33 39 50 / 56,5
Calibration interval 5 years
Service life, years, not less 12

Rotary gas meters RVG are intended for commercial and technological metering of flows of purified and dried gaseous media: natural gas, propane, hydrogen, air, nitrogen and inert gases.

The RVG rotary meter works on the principle of displacement of a strictly defined volume of gas by rotating rotors. The volume of the displaced gas is determined by the volume of the meter's measuring chamber formed by the inner surface of the housing and the surfaces of two rotors synchronously rotating in opposite directions. The rotary motion of the rotors is transmitted through the reducer and the magnetic coupling to an 8-bit counting mechanism, which registers the number of revolutions of the rotors, and, consequently, the volume of gas that has passed through the counter.

The RVG gas meter registers the gas volume under operating conditions. To adjust the measured gas volume to the volume under standard conditions, the RVG meter can be optionally equipped with an electronic corrector of the type or.

Specifications:

Name
Du, mm
Qmax, m3 / h
Pmax, MPa
Measuring range Qmin / Qmax
Feel threshold (m3 / h)
Weight, kg
50 25 1,6 1:30 0,10 12
50 40 1,6 1:30, 1:50, 1:65 0,10 12
50 65 1,6 1:30, 1:50, 1:65, 1:80 0,10 12
50 100 1,6 1:30, 1:50, 1:65, 1:80, 1:100, 1:160 0,10 12
80 160 1,6 0,16 16
80 250 1,6 0,25 33
100 400 1,6 0,40 39
100, 150 650 1,6 0,40 50/56

Measuring complexes based on the RVG gas meter: (temperature correction) and (temperature and pressure correction)


Main settings:

  • Measured flow rate range from 0.8 m3 / h to 650 m3 / h;
  • Working gas pressure no more than 1.6 MPa;
  • Flow rate measurement range Qmin / Qmax: up to 1: 100 (up to 1: 160 for G400)
  • Measurement error:

No more than ± 1% in the flow rate range from 0.1Qmax to Qmax;

No more than ± 2% in the flow rate range from Qmin to 0.1Qmax;

  • Temperature ranges:

Basic information:

Measured flow rate range: from 0.6 m3 / h to 650 m3 / h

Flow rate measurement range Qmin / Qmax: up to 1: 160

Calibration interval: 5 years

Price on request

Rotary gas meters are devices for measuring the volume of gas, the principle of their operation is based on the displacement of gas by rotors. They record the volume of gas under operating conditions.

To bring the measured value to the normal volume, electronic volume correctors such as EK-88, TS-90, EK-260 are used. Gas consumption range: from 0.8 m3 / h to 400 m3 / h. Maximum working pressure: 1.6 MPa.

Application area

Medium: natural gas, city gas, propane, inert gases, air. Industries: gas supply, heat power engineering, chemical industry. Tasks: measurement, control, automatic regulation.

Distinctive features

Over the years, RVG gas meters have proven themselves excellently in operation, especially in cases where high measurement accuracy and compact design are required. Rotary gas meters type RVG are the ideal addition to turbine meters for flow rates from 0.8 m3 / h to 400 m3 / h. High quality structures, components, materials guarantee high accuracy of measurements, durability and reliability of work. RVG gas meters are equipped with two low-frequency E1 impulse transmitters (reed contact). At the request of the customer, RVG gas meters are equipped with an E300 medium-frequency impulse sensor and an A1K high-frequency sensor. The combination of different types of pulse transmitters allows the RVG gas meter to be used in automatic regulation and control systems.

RVG gas meters are distinguished by:

  • low inertia of rotors at variable loads (costs);
  • low pressure loss (20 - 40 mm H2O)

Installation and maintenance

Due to its operating principle, the installation of the RVG gas meter does not require straight pipe runs. Installation can be carried out both on the horizontal and on the vertical section of the gas pipeline. The oil level must be regularly checked and maintained. During operation, it is recommended to use filters or a conical sieve to capture particles larger than 0.25 mm. If the gas is very contaminated, then an additional filter must be used, which captures particles larger than 0.05 mm.

Technical characteristics of industrial gas meters RVG

Counter type V (dm 3) Sensitivity threshold (m 3 / h) Qmin (m 3 / h) Qmin (m 3 / h)
G16 0,56 0,1 0,8 1,3
G25 0,56 0,1 0,8 2
G40 0,56 0,1 1 3,2
G65 0,56 0,1 1 5
G100 1,07 0,16 1,6 8
G160 2,01 0,25 2,5 13
G250 2,54 0,4 4 20
Qmax (m 3 / h) 2 * LF (E1) (imp / m 3) (standard) MF (E300) (imp / m 3) (optional) HF (A1K) (imp / m 3) (additional) p (mbar) at Qmax in nature. gases, = 0.83kg / m 3
25 10 200 14025 0,2
40 10 200 14025 0,5
65 10 200 14025 1,2
100 10 200 14025 2,6
160 1 20 7528 2,3
250 1 20 3882 2,9
400 1 20 3187 3,9